ToxiRAE Pro Single Sensor Gas Detector by RAE Systems from Honeywell

The ToxiRAE Pro single gas detectors from Honeywell's RAE systems range of portable gas detection are compact, reliable and easy to use offering the flexibility of easily swappable sensors that will allow you to monitor for different gases in different situations. Wireless monitoring for toxic gases and oxyen will keep your workers safe by transmitting collected data to a central command location in real time.

The ToxiRAE Pro won't get in the way of workers doing their jobs and provides unmistakable five-way local and remote alarms if a threat is detected or a man is down.

It also offers the flexibility of easily swappable sensors to monitor for different gases in different situations.

Single gas detector for LEL / O2 / CO / H2S / SO2 / CO2 / NH3 / CI2 / CI02 / Et0-A / Et0-B / HCH0 / H2 / CH3-SH / NO / PH3

 

 This email address is being protected from spambots. You need JavaScript enabled to view it.

 

Features
Applications
Specifications
Sensor Specifications
Accessories
PDF Download

  • Personal wireless monitor for toxic gases and oxygen 
  • Swap out sensors for different gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, hydrogen cyanide, nitric oxide, phosphine, sulfur dioxide, and more
  • Sensors store calibration data even when swapped out
  • 5-way local and remote wireless alarm system
  • Largest display in class
  • Water-, dust-, and shock-resistant
  • Compatible with AutoRAE 2 (Fully automatic bump testing and calibration)
  • Built-in man-down alarm
  • Most sensors can be shared with MultiRAE instrument family

  • Clandestine Labs
  • Emergency Response
  • Exploration
  • Fire Overhaul
  • Fracking
  • Hazmat Response
  • Plant Shutdown & Turn-Around
  • Residential Calls
  • Urban Search & Rescue
  • Worker Exposure

Size 11.8 x 6 x 3 cm
Weight  220g
Sensor  Over 20 intelligent interchangeable field-replaceable electrochemical sensors
Battery  Rechargeable Li-ion battery 
- Operating Time: > 30 hours (normal operation, non-wireless) - Recharge Time: < 4 hours through charging cradle
- Recharge Time: < 4 hours through charging cradle
Display Graphical LCD display iwth white LED backlighting (activated when monitor is in alarm or with a button press)
Display Readout - Real-time reading of gas concentrations in parts per million (ppm) or mg/m3, battery status; data logging on/off: wireless on/off and reception quality
- STEL, TWA and peak values
Keypad 2 buttons for operation and programming 
Sampling Diffusion 
Calibration Automatic AutoRAE 2 Test and Calibration System2 or manual 
Alarm Modes - Wireless remote alarm notifications; audible (95dB @ 30cm), vibration, visible alarm (flashing bright red LEDs) and on-screen indication of alarm conditions
- Man Down Alarm with pre-alarm and real-time remote wireless notification
Datalogging - Continuous datalogging with a three-month capacity (at one-minute intervals)
- User-configurable datalogging interval (from 1 to 3,6000 seconds)
Communication & Data Download - Data download and instrument set-up on PC via charging and PC comm. cradle 
- Data download via AutoRAE 2 Automatic TEst and Calibration System
- Wireless data and status transmission1 via built-in RF modem (optional)
Wireless Network ProRAE Guardian Real-Time Wireless Safety System or Closed-Loop Network with the EchoVIew Host
Wireless Range (Typical) ToxiRAE Pro to Mesh Router, EchoView Host or Mesh Reader2 - 200 metres 
ToxiRAE Pro at RAELink3 MEsh or RAELink3 Z1 Mesh modems - 100 metres
Operating Temperature -20ºc to +55ºc 
Humidity 0% to 95% relative humidity (non-condensing)
Dust & Water Resistance IP65 rating for dust and water ingress protection 
Safety Certifications ATEX: CE Ex II 1G, Ex ia IIC Ga T4   / IECEx: Ex ia IIC Ga T4
EMC / RFI EMC directive: 2004/108/EC
Warranty - Two years on non-consumable components and CO, H2S and O2 sensors 
- One year on all other sensors, battery and other consumable parts
Wireless Frequency ISM license-gree bank, IEEE 802.15.4 Sub 1GHz
Wireless Approvals FCC Part 15, CE R&TTE
Radio Module Supports RM9000

1 Wireless units have a functioning RF modem and are ready for wireless deployments; non-wirelss units cannot be upgraded to wireless. Additional equipment and/or software licenses may be required to enable remote wireless monitoring and alarm transmission.

2 Contact Aegis Sales & Service for availability

3 It is recommended that sensors are calibrated on installation

SPECIFICATIONS ARE SUBJECT TO CHANGE

 

 

 Sensor Order Code Range Resolution
 Ammonia (NH3) GDC03-0950-000 0 to 100 ppm 1 ppm
 Carbon Monoxide (CO) GDC03-0906-000 0 to 500 ppm 1 ppm
 Carbon Monoxide (CO), Ext. Range GDC03-0903-000 0 to 2,ooo ppm 10 ppm
 Carbon Monoxide (CO), H2 - comp GDC03-0979-000 0 to 2,000 ppm 10 ppm
 Chlorine (CI2) GDC03-0978-000 0 t0 50 ppm 0.1 ppm
 Chlorine Dioxide (CI02) GDC03-0956-000 0 to 1 ppm 0.03 ppm
 Ethylene Oxide (Et0-A) GDC03-0954-000 0 to 100 ppm 1 ppm
 Ethylene Oxide (Et0-B) GDC03-0922-100 0 to 10 ppm 0.1 ppm
 Ethylene Oxide (Et0-C, HR), Ext. Range GDC03-0923-100 0 to 500 ppm 10 ppm
 Formaldehyde (HCH0) GDC03-0982-000 0 to 10 ppm 0.05 ppm
 Hydrogen (H2) GDC03-0981-000 0 to 1,000 ppm 10 ppm
 Hydrogen Sulfide (H2S) GDC03-0907-001 0 to 100 ppm 0.1 ppm
 Hydrogen Sulfide (H2S), Ext. Range GDC03-0904-000 0 to 1,000 ppm 1 ppm
 Methyl Mercaptan (CH3-SH) GDC03-0980-000 0 to 10 ppm 0.1 ppm
 Nitric Oxide (N0) GDC03-0974-000 0 to 250 ppm 0.5 ppm
 Nitrogen Dioxide (N02) GDC03-0975-000 0 to 20 ppm 0.1 ppm
 Oxygen (O2) GDC03-0942-000 0 to 30% Vol. 0.1% Vol
 Phosphine (PH3) GDC03-0976-000 0 to 20 ppm 0.1 ppm
 Sulfur Dioxide (S02) GDC03-0973-100 0 to 20 ppm 0.1 ppm

 

 

AutoRAE 2 Calibration Dock for the ToxiPro by RAE Systems Honeywell

AutoRAE 2 Automatic Test & Calibration Dock

Simplify bump testing and calibration of your RAE Systems gas monitors with the AutoRAE 2. Versatile and modular, it can be deployed as a single, stand-alone unit to calibrate one instrument at a time, or networked to support up to 10 units at once and calibrate for up to five distinct gases. One-touch bump testing and single-button operation for calibration make it easy to use. 

 

COMING SOON

 

Line Marking Equipment Quote Request

Tell what you are interested in or your application and we will help with the best option for your needs.

  

Please select the required application and equipment interests

We can also have your line marker repaired. Call us today to organise your line marker repair.

Privacy Policy - your details are private and will not be sold/given to a third party.

Portable Gas Detector Warranty Registration

Warranty Registration - Gas Detection

Warranty Registration - Portable Gas Detector

Register your Portable Gas Detection

  
Privacy Policy - your details are private and will not be sold/given to a third party.

Warranty Registration - Sentech Refrigerant Monitor

To validate the Warranty on your Sentech Refrigerant Monitor please complete this form and submit to return it to Aegis Sales & Service / Techinspect within 30 days of installation.

Please provide the relevant system information: Installation Address, Company Name and/or Building Name, Sentech Model and Serial Number.

  
  

Please provide required information on the installation of the system.

  
  

I hereby certify that the above SenTech equipment has been installed and inspected in accordance with the installation and operation manual and is in satisfactory operating condition.

  
Privacy Policy - your details are private and will not be sold/given to a third party.

Book Your Loner Demo

Book your Lone Worker Device Demonstration

  
Privacy Policy - your details are private and will not be sold/given to a third party.

Simply complete this form and one our qualified staff will contact you or phone the office on 1800 234 477.

  
Privacy Policy - your details are private and will not be sold/given to a third party.

Contact Us - Roof Safety Systems

Simply complete this form and one our qualified staff will contact you or phone the office on 1800 234 477.

  
Privacy Policy - your details are private and will not be sold/given to a third party.

Contact Us - Roof Safety Systems - Latchways

Please complete the details below and one of our Roof Safety Professionals will be in contact to discuss your system needs.

  
Privacy Policy - your details are private and will not be sold/given to a third party.

Simply complete this form and one our qualified staff will contact you or phone the office on 1800 234 477.

  
Privacy Policy - your details are private and will not be sold/given to a third party.

Request Your G7 Portable Gas Detector & Lone Worker Monitor Demo

  
Privacy Policy - your details are private and will not be sold/given to a third party.

6 Drawer Tool Box With BBS
7 Drawer Roll Cabinet With BBS
Vacuum Formed Insert Tray With Tools
45 Piece 1/4" & 3/8" Drive Socket Set
43 Piece 1/2" Drive Metric & AF Socket Set
Vacuum Formed Insert Tray With Tools
7 Piece Punch & Chisel Set
Vacuum Formed Insert Tray With Tools
54 Piece 10mm Shank Bit Set
Vacuum Formed Insert Tray With Tools
200mm Combination Pliers
200mm Long Nose Pliers
180mm Diagonal Cutting Pliers
Vacuum Formed Insert Tray With Tools
24 Piece Metric & AF Combination Spanner Set
Vacuum Formed Insert Tray With Tools
175mm Auto Loading Utility Knife
7 Piece Blade & Phillips Screwdriver Set
250mm Curved Jaw Multigrip Pliers
250mm Locking Pliers
450g (16oz) Ball Pein Hammer
250mm Adjustable Wrench
150mm Adjustable Wrench
30 Piece Hex Key Set
300mm Hacksaw

Privacy Policy - your details are private and will not be sold/given to a third party.
  

Please select the most appropriate time and contact method for one of our team to contact your regarding your query.

Privacy Policy - your details are private and will not be sold/given to a third party.
Privacy Policy - your details are private and will not be sold/given to a third party.