Call Us Now

1800 234 477

RAE Systems by Honeywell MultiRAE The MultiRAE by Honeywell is the most advanced portable chemical detector on the market. With the f.. Product #: GDMAA3 based on 0 reviews

MultiRAE Portable Gas Detection

Brand: RAE Systems by Honeywell
Product Code: GDMAA3
Contact: 07 3865 1139
- +

The MultiRAE by Honeywell is the most advanced portable chemical detector on the market.

With the flexibility of up to six gas sensors and the convenience of wireless portability, this multi-gas monitor is versatile and customisable, while delivering real-time access to instrument readings and alarm status from any location.

Choose from 25 sensor options including LEL, PID, NDIR, and exotics that can be easily changed in the field. It has five built-in alarms, including man down, and wireless connectivity to your command center, MultiRAE delivers vital information for fast incident response. 

Suitable for: Confined Space Entry / Fracking / Hazmat Response / Emergency Response / Clandestine Labs / Environmental cleanups & Remediation / Industrial Hygiene / Oil & Gas - plant shutdowns & turn-around

Multi gas detector VOC / PID / LEL / H2S / CO / O2 / CO2 / SO2

 

 
  • 25 field-interchangeable sensor options, including PID, NDIR, and exotics like ammonia, chlorine, and formaldehyde
  • Five local and remote alarms, including man down
  • Dust-tight and waterproof (IP65-rated)
  • Rugged design
  • Onboard gas libraries include 190 VOCs and 55 combustible gases
  • Longest battery run-time in its class
  • Intuitive, icon-driven interface
  • Flippable screen
  • Large buttons for easy navigation even with up to three glove layers
  • Continuous data logging — six months for five sensors 24/7
  • Fully automated bump testing and calibration with AutoRAE 2
  • Optional integrated wireless
 
  • Clandestine Labs
  • Confined Space Entry
  • Emergency Response
  • Environmental Cleanups/Remediation
  • Exploration
  • Fire Overhaul
  • Fracking
  • Hazmat Response
  • Plant Shutdown & Turn-Around
  • Urban Search & Rescue
 Size 19.3 x 9.7 x 6.6 cm
 Weight  880g 
 Sensors  Over 25 intelligent interchangeable field-replaceable sensors including PID for VOCs, electrochemical sensors for toxic gases and oxygen, combustible LEL and NDIR sensors and CO2 NDIR sensors
 Battery Options, Runtime, Recharge Time  - Rechargeable Li-ion 12 hr runtime, < 6 hr recharge time
  - Extended duration Li-ion  18 hr runtime, < 9 hr recharge time
  - Alkaline adapter with 4 x AA batteries 6 hr runtime
 Display Monochrome graphical LCD display (128 x 160) with backlighing. Auytomatic screen "flip" feature
 Display Readout - Real-time reading of gas concentrations; PID measurement gas and correction factor; Man Down Alarm on/off; visual compliance indicator; battery status; datalogging on/off; wireless on/off and reception quality
  - STEL, TWA, peak and minimum values
 Keyboard Buttons 3 operation programming keys (Mode, Y/+ and N/-)
 Sampling Built-in pump. Average flow rate: 250 cc/min. Auto shutoff in low-flow conditions
 Calibration Automatic with AutoRAE 2 Test and Calibration System or manual
 Alarms Wireless remote alarm notification; audible (95dB @ 30cm), vibration, visible (flashing bright red LEDs) and on-screen indication of alarm conditions
  - Man Down Alarm with pre-alarm and real-time remote wirelss notification1
 Data Logging Continuous datalogging (6 months for 5 sensors at 1 minute intervals, 24/7) - user configurable datalogging intervals (from 1 to 3,600 seconds)
 Communication & Data Download - Data download and instrument set-up and upgrades on PC via desktop charging and PC comm. cradle, travel charger or AutoRAE 2 Automatic Test and Calibration system
  - Wireless data and alarm status transmission via built-in RF modem (optional)
 Wirelss Network ProRAE Guardian REal-Time Wireless Safety System or EchoView Host-based Closed-Loop System
 Wireless Range (typical) MultiRAE to RAELink3 [Z1] Mesh modem - 100 metres
  MultiRAE to EchoView Host, RAEMesh Reader or RAEPoint - 200 metres
 Operating Temperature -20ºc to +50ºc
 Humidity 0% to 95% relative humidity (non-condensing)
 Dust & Water Resistance IP65 ingress protection rating (dust-tight and waterproof against hosing jets coming from all directions)
 Safety Certifications CSA: Class I, Div. 1, Groups A, B, C, D, T4       Class II, Div. 1, Groups E, F, G T85ºc
  ATEX: 0575 II 1G Ex ia IIC T4      2G Ex ia d IIC T4 Gb with IR Sensor installed      IM1 Ex ia I Ma
  IECEx: Ex  ia IIC T4 Ga     EX ia d IIC T4 Gb with IR Sensor installed     IM1 Ex ia I Ma
  IECEx/ANZEx:  Ex ia IIC T4 Ga      Ex ia d IIC T4  Gb  with IR Sensor installed     Ex ia I Ma
 EMI/RFI
EMC directive: 2004/108/EC
EMI and ESD Test: 100Mhz to 4GHz 30V/m, no alarm
Contact: +4kV
Air: +8kV, no alarm
 Performance Tags LEL CSA C22.2 No. 152, isa-12.13.01
 Warranty - Two years on non-consumable components and catalytic LEL, CO H2S and O2 sensors
  - One year on all other sensors, pump, battery and other consumable parts
 Wireless Frequency ISM license free band. IEEE 802.15.4 Sub 1 GHz     Wi-Fi 802.11 b/g 
 Wireless Approvals FCC Part 15, CE R&TTE
 Radio Module Supports RM900A

 

1 Additional equipment and/or software licenses may be required to enable remote wireless monitoring and alarm transmission.
2 RAE by Honeywell recommends calibrating sensors on installation.
3 A two-gas combination sensor is required for a 6-gas configuration.
4 Specifications are subject to change.
5 Specification for non-wireless monitors.

 

 PID Sensor
 Range Resolution 
 VOC 10.6 eV 0 to 5,000 ppm 0.1 ppm
 Combustible Sensors Range Resolution
 Catalytic LEL 0 to 100% LEL 1% LEL
 NDIR (0 - 100% LEL Methane) 0 to 100% LEL 1% LEL
 NDIR (0 - 100% Vol. Methane)
0 to 100% Vol. 0.1% Vol.
 Carbon Dioxide Sensor
Range Resolution
 Carbon Dioxide (CO2) 0 to 50,000 ppm 100 ppm
 Electrochemical Sensors Range  Resolution
 Ammonia (NH3) 0 to 100 ppm  1 ppm
 Carbon Monoxide (CO) 0 to 500 ppm 1 ppm
 Carbon Monoxide (CO), Ext. Range 0 to 2,000 ppm 10 ppm
 Carbon Monoxide (CO), H2-comp. 0 to 500 ppm 10 ppm
 Carbon Monoxide (CO) + Hydrogen Sulfide (H2S) Combo 0 to 200 ppm 0.1 ppm
 Chlorine (CI2) 0 to 50 ppm 0.1 ppm
 Chlorine Dioxide (CIO2) 0 to 1 ppm 0.03 ppm
 Ethylene Oxide (EtO-A) 0 to 100 ppm 0.5 ppm
 Ethylene Oxide (EtO-B) 0 to 10 ppm 0.1 ppm
 Formaldehyde (HICHO) 0 to 10 ppm 10 ppm
 Hydrogen (H2)9 0 to 1,000 ppm 10 ppm
 Hydrogen Cyanide (HCN) 0 to 50 ppm 0.5 ppm
 Hydrogen Sulfide (H2S) 0 to 100 ppm 0.1 ppm
 Hydrogen Sulfide (H2S), Ext. Range
0 to 1,000 ppm 1 ppm
 Methyl Mercaptan (CH3-SH) 0 to 10 ppm 0.1 ppm
 Nitric Oxide (NO) 0 to 250 ppm 0.5 ppm
 Nitrogen Dioxide (NO2) 0 t0 20 ppm 0.1 ppm
 Oxygen (O2) 0 to 30% Vol. 0.1% Vol.
 Phosphine (PH3) 0 to 20 ppm 0.1 ppm
 Sulphur Dioxide (SO2) 0 to 20 ppm 0.1 ppm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
There are no reviews for this product.
Write a review
BadExcellent
Facebook comment

Visit Our Showroom

1/119 Delta Street Geebung, QLD 4034

Phone: 07 3865 1139

Email: sales@aegissales.com.au

Business Hours

Mon - Fri -------------- 8:00am to 4.30pm

Sat - Sun ------------- Closed

Join Us

Follow Aegis Sales & Service on Facebook   Connect with Aegis Sales & Service on Linkedin  Connect with Aegis Sales & Service on Google Plus

Newsletter

 
 

Line Marking Equipment Quote Request

Tell what you are interested in or your application and we will help with the best option for your needs.

  

Please select the required application and equipment interests

We can also have your line marker repaired. Call us today to organise your line marker repair.

Portable Gas Detector Warranty Registration

Warranty Registration - Gas Detection

Warranty Registration - Portable Gas Detector

Register your Portable Gas Detection

  

Warranty Registration - Sentech Refrigerant Monitor

To validate the Warranty on your Sentech Refrigerant Monitor please complete this form and submit to return it to Aegis Sales & Service / Techinspect within 30 days of installation.

Please provide the relevant system information: Installation Address, Company Name and/or Building Name, Sentech Model and Serial Number.

  
  

Please provide required information on the installation of the system.

  
  

I hereby certify that the above SenTech equipment has been installed and inspected in accordance with the installation and operation manual and is in satisfactory operating condition.

  

Book Your Loner Demo

Book your Lone Worker Device Demonstration

  

Simply complete this form and one our qualified staff will contact you or phone the office on 1800 234 477.

  

Contact Us - Roof Safety Systems

Simply complete this form and one our qualified staff will contact you or phone the office on 1800 234 477.

  

Contact Us - Roof Safety Systems - Latchways

Please complete the details below and one of our Roof Safety Professionals will be in contact to discuss your system needs.

  

Simply complete this form and one our qualified staff will contact you or phone the office on 1800 234 477.